SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 04/2020, A5E50074509B AA
165
Commissioning
8
8.1 Manufacturer declaration
WARNING
Danger to life through the use of an incomplete machine
If you use a machine that does not conform to the 2006/42/EU decree, there is the danger
of death, severe injury and/or material damage.
Commission the machine only when it conforms to the regulations of the EU
2006/42/EU machine decree and the conformity has been declared.
8.2 Safety instructions
WARNING
Electric shock when connected to inadequately grounded line supplies
In the case of a fault, connecting a motor to an inadequately grounded line supply can
result in death, severe injury and motor damage.
Connect motors, as part of the drive system, to TN and TT line supplies with a grounded
neutral point or to IT line supplies.
Ensure that the SINAMICS devices and motors are compatible with the residual current
device according to EN 61800-5-1 before you connect the devices and motors to the
line supply using residual current devices (RCDs).
For line supplies with grounded line conductor, e.g. TT line supplies, use an isolating
transformer with grounded neutral point (on the secondary side) between the line supply
and the drive system, so that the motor insulation is not overstressed.
When connected to IT line supplies, a monitoring device must signal the first fault
between an active part and ground. Remove this fault immediately.

Table of Contents

Other manuals for Siemens SIMOTICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS Series and is the answer not in the manual?

Siemens SIMOTICS Series Specifications

General IconGeneral
Product brand nameSIEMENS
Product designationSIMOTICS
Efficiency ClassIE1, IE2, IE3, IE4
Ambient Temperature+60°C
AltitudeUp to 4000 m
Frame Size63 to 355
Protection ClassIP55, IP56, IP65

Related product manuals