EasyManuals Logo

Siemens SIMOTICS Series Hardware Installation Manual

Siemens SIMOTICS Series
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Description
3.3 Technical features and system requirements for built-in motors
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 04/2020, A5E50074509B AA
25
3.3 Technical features and system requirements for built-in motors
3.3.1 Directives and standards
Standards that are complied with
The motors of the type series SIMOTICS S, SIMOTICS M, SIMOTICS L, SIMOTICS T,
SIMOTICS A, called "SIMOTICS motor series" below, fulfill the requirements of the following
directives and standards:
EN 60034-1 - Rotating electrical machines Dimensioning and operating behavior
EN 60204-1 - Safety of machinery Electrical equipment of machines; general
requirements
Where applicable, the SIMOTICS motor series are in conformance with the following parts of
EN 60034:
Feature
Standard
Degree of protection
EN 60034-5
Cooling
1)
EN 60034-6
Type of construction
EN 60034-7
Connection designations EN 60034-8
Noise levels
1)
EN 60034-9
Temperature monitoring
EN 60034-11
Vibration severity grades
1)
EN 60034-14
1)
Standard component, e.g. cannot be applied to built-in motors
Relevant directives
The following directives are relevant for SIMOTICS motors.
European Low-Voltage Directive
SIMOTICS motors comply with the Low-Voltage Directive 2014/35/EU.
European Machinery Directive
SIMOTICS motors do not fall within the scope covered by the Machinery Directive.
However, the use of the products in a typical machine application has been fully assessed
for compliance with the main regulations in this directive concerning health and safety.
European EMC Directive
SIMOTICS motors do not fall within the scope covered by the EMC Directive. The products
are not considered as devices in the sense of the directive. Installed and operated with a
converter, the motor - together with the Power Drive System - must comply with the
requirements laid down in the applicable EMC Directive.

Table of Contents

Other manuals for Siemens SIMOTICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS Series and is the answer not in the manual?

Siemens SIMOTICS Series Specifications

General IconGeneral
Product brand nameSIEMENS
Product designationSIMOTICS
Efficiency ClassIE1, IE2, IE3, IE4
Ambient Temperature+60°C
AltitudeUp to 4000 m
Frame Size63 to 355
Protection ClassIP55, IP56, IP65

Related product manuals