Decommissioning and disposal
11.2 Decommissioning
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 04/2020, A5E50074509B AA
187
11.2.2 Disassembling the motor
This chapter provides instructions on disassembling the motor.
Precondition
Disassemble the motor with appropriate expertise.
When disassembling synchronous motors, observe the safety instructions for handling
permanent magnets.
Special safety notices for handling built-in motors (Page 19)
Procedure for disassembling a synchronous motor
WARNING
Injury or material damage if not correctly disassembled
If you do not correctly disassembly direct drives or their components (especially
components with permanent magnets), then this can result in death, severe injury and/or
material damage.
Ensure that direct drives and their associated components are correctly disassembled.
Note
Disassembling the synchronous motor
The motor must be disassembled
by an authorized company or the manufacturer.
Procedure for disassembling an asynchronous motor
1. Disassemble the motor.
2. Dispose of the motor parts or return the motor parts to the manufacturer.
Dispose of the motor parts according to the instructions in Chapter "Disposal (Page 188)".

Table of Contents

Other manuals for Siemens SIMOTICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS Series and is the answer not in the manual?

Siemens SIMOTICS Series Specifications

General IconGeneral
Product brand nameSIEMENS
Product designationSIMOTICS
Efficiency ClassIE1, IE2, IE3, IE4
Ambient Temperature+60°C
AltitudeUp to 4000 m
Frame Size63 to 355
Protection ClassIP55, IP56, IP65

Related product manuals