Operation
9.3 Faults and how to resolve them
SIMOTICS M-1FE2 built-in motors
Hardware Installation Manual, 04/2020, A5E50074509B AA
181
In this regard, observe the relevant chapters in the documentation associated with the
components of the complete drive system.
Repair any damage that occurred on the machine/motor spindle.
Note
When operating the motor spindle with a converter, refer also to the Operating
Instructions of the frequency converter if electrical faults occur.
Table 9- 1 Key to causes of faults and remedial measures
No.
Causes of fault
Remedial measures
A Overload Reduce load
B Interruption of a phase in the supply ca-
ble
Check frequency converters, feeder cables and contactors, if necessary
C Interruption of a phase in the supply after
switching on
Check frequency converters, feeder cables and contactors, if necessary
D Converter output voltage too high, fre-
quency too low
Check the settings on the frequency converter, perform automatic motor
identification
E
Stator winding incorrectly connected
Check the winding circuit and, if applicable, the wiring of the contactors
F Winding short circuit or phase short cir-
cuit in stator winding
Measure the winding resistances and insulation resistances, repair after
consultation with manufacturer
G
Cooling water not connected/switched off
Check cooling water connection/switch on cooling water
Water connection / pipes defective
Locate leaks and seal as necessary, or consult the manufacturer
H
Cooling water flow rate too low
Increase cooling water flow rate
Inlet temperature too high
Set correct inlet temperature
I Heat dissipation impeded by deposits Clean the surface of the drives and ensure that the cooling air can flow
in and out unimpeded
Cooling air inlet/outlet is blocked by for-
eign bodies
Remove the blockage and ensure that the cooling air can flow in and
out unimpeded
J Insufficient shielding for motor and/or
encoder cable
Check the shielding and grounding
K
Excessive drive controller gain
Adjust the controller
L
Rotating parts are grinding
Determine cause and adjust parts concerned
Foreign bodies within the motor
Repair by manufacturer
Bearing damage
Repair by manufacturer
M
Rotor not balanced
Decouple rotor and rebalance
N
Rotor out of round, shaft bent
Please consult the manufacturer
O
Poor alignment
Align machine set, check coupling
P Cooling water pipes/water connection
defective
Locate leaks and seal as necessary, or consult the manufacturer

Table of Contents

Other manuals for Siemens SIMOTICS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS Series and is the answer not in the manual?

Siemens SIMOTICS Series Specifications

General IconGeneral
Product brand nameSIEMENS
Product designationSIMOTICS
Efficiency ClassIE1, IE2, IE3, IE4
Ambient Temperature+60°C
AltitudeUp to 4000 m
Frame Size63 to 355
Protection ClassIP55, IP56, IP65

Related product manuals