3.3 Technical features and system requirements for built-in motors
SIMOTICS M-1FE2 built-in motors
40 Hardware Installation Manual, 04/2020, A5E50074509B AA
Operation with booksize power section
Practical advantages:
You can arrange the converter components variably in the work machine.
Less installation space is required compared with a chassis module.
Operation with chassis power section
No suitable VPM is currently available for operation of the motor on a chassis power section.
Reduce the permitted maximum speed of the motor to the converter maximum speed
n_max_Invs specified in the datasheets.
Note
Al
ways operate the power sections with a pulse frequency of f
p
= 4 kHz.
Note
The 1FE218
motors do not require a series reactor.