Interfaces
3.2 DRIVE-CLiQ interfaces
D4x5
38 Manual, 05/2009
Non-usable interfaces
Table 3- 2 Overview of interfaces that cannot be used for SIMOTION D
Interface name Interface Connector type
RS232 interface X140 9-pin SUB-D pins
3. Ethernet interface (if fitted) X127 RJ45 socket connector
Interface for BOP - 8-pin multipoint connector
3.2 DRIVE-CLiQ interfaces
DRIVE-CLiQ interfaces
All SINAMICS S120 drive system components, including the motors and encoders, are
interconnected by a shared serial interface called DRIVE-CLiQ. The standardized cables and
connectors reduce the variety of different parts and cut storage costs.
DRIVE-CLiQ has the following properties:
Automatic detection of components by the control unit
Standardized interfaces to all components
Uniform diagnostics down to the components
Complete service down to the components
24 V/450 mA per DRIVE-CLiQ interface are provided for the connection of encoders and
measuring systems.
Note:
The DRIVE-CLiQ cables with 24 V supply should be used only for components that
require this (e.g. motors with a DRIVE-CLiQ interface).