Parameter list 01.04
11-52 SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
PNU Description Value range
[Unit]
No. indices See
Change
r653
(G183)
Display of status word 2
Representation on operator panel (PMU):
3210
4
5
6
7
89101112131415
Segments 0 to 15 correspond to bits 16 to 31 of the status word
Segment ON: Corresponding bit is in log. "1" state
Segment OFF: Corresponding bit is in log. "0" state
Ind: None
Type: V2
P052 = 3
The following parameters are used to select the binectors (some of which are gated with one another or with other signals) to be applied
to the individual bits of the control word.
The settings of all these parameters are as follows:
0 = binector B0000
1 = binector B0001
etc.
The functions and logic operations are also shown on Sheets G180 and G181 in Section 8.
Control word 1
P654
*
BDS
(G130)
Source for control word 1, bit0
(0=OFF1, 1=ON; ANDed with terminal 37)
All binector numbers
1
Ind: 2
FS=9358
Type: L2
P052 = 3
P051 = 40
Offline
P655
*
BDS
(G180)
1. 3rd source for control word 1, bit1
(0=OFF2; ANDed with 2
nd
and 3
rd
sources for bit1)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P656
*
BDS
(G180)
2. 3rd source for control word 1, bit1
(0=OFF2; ANDed with 1
st
and 3
rd
sources for bit1)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P657
*
BDS
(G180)
3. 3rd source for control word 1, bit1
(0=OFF2; ANDed with 1
st
and 2
nd
sources for bit1)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P658
*
BDS
(G180)
1. 3rd source for control word 1, bit2
(0=OFF3=Fast stop; ANDed with 2
nd
and 3
rd
sources for bit2)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P659
*
BDS
(G180)
2. 3rd source for control word 1, bit2
(0=OFF3=Fast stop; ANDed with 1
st
and 3
rd
sources for bit2)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P660
*
BDS
(G180)
3. 3rd source for control word 1, bit2
(0=OFF3=Fast stop; ANDed with 1
st
and 2
nd
sources for bit2)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P661
*
BDS
(G180)
Source for control word 1, bit3
(0=pulse disable, 1=enable; ANDed with terminal 38)
All binector numbers
1
Ind: 2
FS=9350
Type: L2
P052 = 3
P051 = 40
Offline
P662
*
BDS
(G180)
Source for control word 1, bit4
(0=set ramp-function generator to zero, 1=enable ramp-function generator)
All binector numbers
1
Ind: 2
FS=9381
Type: L2
P052 = 3
P051 = 40
Offline
P663
*
BDS
(G180)
Source for control word 1, bit5
(0=ramp-function generator stop, 1=ramp-function generator start)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P664
*
BDS
(G180)
Source for control word 1, bit6
(0=enable setpoint, 1=disable setpoint)
All binector numbers
1
Ind: 2
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
P665
*
BDS
(G180)
1. 3rd source for control word 1, bit7
(01 transition=acknowledge; ORed with 2
nd
and 3
rd
sources for bit7)
All binector numbers
1
Ind: 2
FS=9367
Type: L2
P052 = 3
P051 = 40
Offline