Parameter list 01.04
11-154 SIEMENS AG 6SG7000-0BA76
SIMOTRAS HD Operating Instructions
PNU Description Value range
[Unit]
No. indices See
Change
11.85 Slot deactivation
U910
(2910)
*
(G101)
Slot deactivation parameter [SW 1.9 and later]
Parameter for deactivating supplementary boards, e.g. during start-up or
troubleshooting (for details of slot identification codes, see diagram under
parameter r063)
i001: -
i002: Slot D
i003: Slot E
i004: Slot F
i005: Slot G
0 Board in slot active
1 Board in slot not active
The deactivated slot is ignored during the search for installed
supplementary boards when the supply voltage is next switched on.
Likewise, activation of a slot does not take effect until the supply voltage
has been switched off and on again.
Note:
Slot E can simply be deactivated to conceal a technology board (large
format).
If a communications board is installed in addition to the technology board,
and the technology board is concealed, then the communications board will
not be processed either.
0 and 1
1
Ind: 5
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
11.86 Parameter for DriveMonitor
U911
to
n949
(2911 to
2949)
These parameters are used by DriveMonitor