01.04 Appendix
SIEMENS AG 6SG7000-0BA76 18-3
SIMOTRAS HD Operating Instructions
Microswitch on SIMOTRAS HE (6GA4625
series)
Corresponding parameter on SIMOTRAS HD
(6SG70 series)
S1 – Override of ramp-function generator in
controlled range
No such setting, as the “zero delay angle” function
is implemented in a different way.
S2 – Speed monitoring Speed monitoring inactive if P590 = P591
S3 – Brake application time monitoring This function must be implemented using free
modules if required (similar to run-back monitoring
on Page K15 in Section 8)
S4 – Controlled operation command The “zero delay angle” command is inactive when
U605 = 0.
S5 – Premature switchover of rotor
contactor stage 1 to "Delay lowering“
mode (counter-torque operation)
U630 (factory setting = -1.0 %) [G119.2]
S6 – I component of current controller P154 (factory setting = 1) [G162.6]
S7 – I component of speed controller P224 (factory setting = 1)
S8 – Selection of type of setpoint input P700 (factory setting = 0) [G113.2]