Communication via EtherNet/IP
4.5 Supported objects
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
99
Link Object, Instance Number: F6 hex
Supported services
Class
Get Attribute all
Get Attribute single
Instance
Get Attribute all
Get Attribute single
Set Attribute single
Table 4- 22 Class Attribute
No.
Service
Type
Name
1
get
UINT16
Revision
2
get
UINT16
Max Instance
3
get
UINT16
Num of Instances
Table 4- 23 Instance Attribute
No.
Service
Type
Name
Value/explanation
1 get UINT32 Interface Speed 0: link down,
10: 10 Mbps,
100: 100 Mbps
2 get Interface Flags Bit 1: Link-Status
Bit 2: Duplex Mode (0: halb duplex, 1 duplex
Bit 35: Automatic state identification
Bit 6: Reset required
Bit 7: Local hardware fault (0 = ok)
3 get ARRAY Physical Address r8935 Ethernet MAC address
4 get_and_
clear
Struct of Interface Coun-
ters
Optional, required if the "Media Counters Attribute"
is implemented.
UINT32
In Octets
Received octets
UINT32
In Ucast Packets
Received Unicast packets
UINT32 In NUcast Pack-
ets
Received non-Unicast packets
UINT32
In Discards
Incoming packets, not processed
UINT32
In Errors
Incoming packets with errors
UINT32 In Unknown Pro-
tos
Incoming packets with unknown protocol
UINT32
Out Octets
Sent octets
UINT32 Out Ucast Pack-
ets
Sent Unicast packets
UINT32 Out NUcast
packets
Sent non-Unicast packets
UINT32
Out Discards
Outgoing packets, not processed
UINT32
Out Errors
Outgoing packets, with errors