EasyManua.ls Logo

Siemens SINAMICS PM240-2 - Current Derating Depending on the Pulse Frequency, 400 V Converters

Siemens SINAMICS PM240-2
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
6.5 400 V converters
Power Module PM240-2
98 Hardware Installation Manual, 01/2020, A5E33294624B AL
6.5.3 Current derating depending on the pulse frequency, 400 V converters
Article number
LO
power
[kW]
Pulse frequency [kHz]
2
4
*)
6
8
10
12
14
16
LO base load output current [A]
6SL3210-1PE11-8 . L1
0.55
1.7
1.7
1.4
1.2
1
0.9
0.8
0.7
6SL3210-1PE12-3 . L1
0.75
2.2
2.2
1.9
1.5
1.3
1.1
1
0.9
6SL3210-1PE13-2 . L1
1.1
3.1
3.1
2.6
2.2
1.9
1.6
1.4
1.2
6SL3210-1PE14-3 . L1 1.5 4.1
4.1
3.5 2.9 2.5 2.1 1.8 1.6
6SL3210-1PE16-1 . L1
2.2
5.9
5.9
5
4.1
3.5
3
2.7
2.4
6SL321 . -1PE18-0 . L1
3
7.7
7.7
6.5
5.4
4.6
3.9
3.5
3.1
6SL3210-1PE21-1 . L0
4
10.2
10.2
8.7
7.1
6.1
5.1
4.6
4.1
6SL3210-1PE21-4 . L0
5.5
13.2
13.2
11.2
9.2
7.9
6.6
5.9
5.3
6SL321 . -1PE21-8 . L0
7.5
18
18
15.3
12.6
10.8
9
8.1
7.2
6SL3210-1PE22-7 . L0
11
26
26
22.1
18.2
15.6
13
11.7
10.4
6SL321 . -1PE23-3 . L0
15
32
32
27.2
22.4
19.2
16
14.4
12.8
6SL3210-1PE23-8 . L0
18.5
38
38
32.3
26.6
22.8
19
17.1
15.2
6SL3210-1PE24-5 . L0
22
45
45
38.3
31.5
27
22.5
20.3
18
6SL3210-1PE26-0 . L0
30
60
60
51
42
36
30
27
24
6SL321 . -1PE27-5 . L0
37
75
75
63.8
52.5
45
37.5
33.8
30
6SL3210-1PE28-8 . L0
45
90
90
76.5
63
54
45
40.5
36
6SL321 . -1PE31-1 . L0
55
110
110
93.5
77
---
---
---
---
6SL3210-1PE31-5 . L0
75
145
145
123.3
101.5
---
---
---
---
6SL3210-1PE31-8 . L0
90
178
178
151.3
124.6
---
---
---
---
Article number
Pulse frequency [kHz]
2
*)
4
6
8
10
12
14
16
LO base load output current [A]
6SL3210-1PE32-1 . L0 110
205
143.5 102.5 82 --- --- --- ---
6SL321 .-1PE32-5 . L0
132
250
175
125
100
---
---
---
---
6SL3210-1PE33-0 .L0 160
302
211.4 151 120.8 --- --- --- ---
6SL3210-1PE33-7 .L0
200
370
259
185
148
---
---
---
---
6SL3210-1PE34-8 .L0
250
477
333.9
238.5
190.8
---
---
---
---
*) Factory setting
The permissible motor cable length depends on the particular cable type and the pulse frequency that
has been selected

Table of Contents

Other manuals for Siemens SINAMICS PM240-2

Related product manuals