EasyManua.ls Logo

Siemens SINAMICS PM240-2 - Ambient conditions

Siemens SINAMICS PM240-2
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
6.2 Ambient conditions
Power Module PM240-2
Hardware Installation Manual, 01/2020, A5E33294624B AL
75
6.2 Ambient conditions
Property
Version
Ambient conditions for transport in the transport packaging
Air-conditioning - 40° C … + 70° C, according to Class 2K4 to EN 60721-3-2:1997
maximum humidity 95% at 40 °C
Mechanical system Shock and vibration permissible according to 1M2 to IEC 60721-3-2:1997
Chemical substances Protected according to Class 2C2 to IEC 60721-3-2:1997
Biological ambient condi-
tions
Suitable according to Class 2B1 to IEC 60721-3-2:1997
Ambient conditions for long-term storage in the product packaging or in transport packaging
Air-conditioning
- 25 °C+ 55° C, according to Class 1K3 to IEC 60721-3-1:1997
Chemical substances
Protected according to Class 1C2 to IEC 60721-3-1:1997
Biological ambient condi-
tions
Suitable according to Class 1B1 to IEC 60721-3-1:1997
Ambient conditions in operation
Installation altitude Up to 1000 m above sea level without limitations
Restrictions for special ambient conditions (Page 105)
Air-conditioning
1)
FSA ... FSC ambient operating temperature
2)
For operation according to Low Overload: -10 °C … +40 °C
For operation according to High Overload: -10 °C … +50 °C
Restrictions for special ambient conditions (Page 105)
FSD ... FSG ambient operating temperature
2)
For operation according to Low Overload: -20 °C … +40 °C
For operation according to High Overload: -20 °C … +50 °C
Restrictions for special ambient conditions (Page 105)
Relative humidity: 595%, condensation not permitted
Oil mist, ice formation, condensation, dripping water, spraying water, splashing water
and water jets are not permitted
Mechanical system Vibration test during operation according to IEC 60068-2-6 Test Fc (sinusoidal)
0 ... 57 Hz: 0.075 mm deflection amplitude
57 ... 150 Hz: 1 g acceleration amplitude
10 frequency cycles per axis
Shock test according to IEC 60068-2-27 Test Ea (half-sine)
5 g peak acceleration
30 ms duration
3 shocks in all three axes in both directions
Chemical substances
FSA … FSC: Protected according to 3C2 to IEC 60721-3-3:2002
FSD … FSG: Protected according to 3C3 to IEC 60721-3-3:2002
Biological ambient condi-
tions
Suitable according to 3B1 to IEC 60721-3-3: 2002
Pollution
Suitable for environments with degree of pollution 2 according to EN 61800-5-1

Table of Contents