EasyManua.ls Logo

Siemens SINAMICS PM240-2 - 200 V converters

Siemens SINAMICS PM240-2
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
6.4 200 V converters
Power Module PM240-2
Hardware Installation Manual, 01/2020, A5E33294624B AL
77
Load cycles and typical applications:
"Low Overload" load cycle
"High Overload" load cycle
The "Low Overload" load cycle assumes a
uniform base load with low
requirements
placed on brief accelerating phases. Typical
applications when designing according to
"Low Overload" include:
Pumps, fans and compressors
Wet or dry blasting technology
Mills, mixers, kneaders, crushers,
agitators
Basic spindles
Rotary kilns
Extruders
The "High Overload" load cycle permits
dynamic accelerating phases at a reduced
base load. Typical applications when de-
signing according to "High Overload" in-
clude:
Horizontal and vertical conveyor
technology (conveyor belts, roller
conveyors, chain conveyors)
Centrifuges
Escalators/moving stairways
Lifters/Lowerers
Elevators
Gantry cranes
Cable railways
Storage and retrieval machines
Typical converter load cycles
Figure 6-1 "Low Overload" and "High Overload" load cycles
6.4 200 V converters
Motors for 200 V Power Modules
For the 200 V Power Modules, induction motors are permissible in the range from
25%150% of the converter power without any restrictions.
Permissible motors
Note
Motors for converter operation
Only use
motors that are suitable for operation with converters with a DC link.