Table 3- 8 Dimensions depend on the Control Unit (CU) and HMI device [mm]
Frame
size
Width
[mm]
Height [mm]
Overall depth in the cabinet [mm]
Without
shield
plate
With shield
plate
T1
with
CU230P-
2
1)
with
CU240B-2
1)
/
CU240E-2
1)
with
CU250S-
2
1)
FSD
275
517
650
141
155
141
158
FSE
354
615
772
141
155
141
158
FSF 384 785 1021 177.5 193 177.5 196
1)
With a Smart Access Module plus 9 mm
With blanking cover or with Operator Panel plus 11 mm.
Table 3- 9 Cooling air clearances, further dimensions and mounting
Frame
size
Power Module depth [mm]
Cooling air clearances [mm]
Fixing/torque
[Nm]
T1 + T2
T1
T2
Top
Bottom
Front
FSD
238.5
141
97.5
350
300
100
10 × M5 / 3.5
FSE
238.5
141
97.5
350
300
100
10 × M5 / 3.5
FSF
358
177.5
180.5
350
300
100
12 × M6 / 5.9
3.4.4 Mounting the shield plates
Use the provided shield plate for strain relief of the line and motor cable as well as the
shield support for the motor cable.
The shield plates and fixings screws are included in the converter accessory kit.