8.5.3.2 Diagnostics via LEDs
LEDs of the Power Stack Adapters
Table 8-4 LEDs of the Power Stack Adapters
LED Color Status Description; cause Remedy
PWR - Off 24 V power supply has failed or is too low
(< 14 V) or internal fuse defective.
Check input voltage.
If input voltage is > 18 V and LED off:
Return component for repair.
Red Continuous
light
24 V power supply is available (>14 V);
internal board voltage fault.
Check input voltage.
If input voltage is > 18 V and LED red:
Return component for repair.
Green Continuous
light
24 V power supply OK.
Internal board voltages OK.
--
RUN /
ERR
- Off The electronic power supply is missing
or lies outside the permissible tolerance
range.
-
Green Continuous
light
The component is ready for operation
and cyclic DRIVE-CLiQ communication
is in progress.
-
Orange Continuous
light
DRIVE-CLiQ communication is being es‐
tablished.
-
Red Continuous
light
At least one fault is present in the com‐
ponent.
LED is controlled irrespective of the cor‐
responding messages being reconfig‐
ured.
Remedy and acknowledge fault.
Green/red 0.5 Hz flashing
light
Firmware download in progress. -
2 Hz flashing
light
Firmware download is complete. Waiting
for POWER ON.
Carry out a POWER ON.
Green/or‐
ange
or
Red/orange
Flashing light Component recognition via LED is acti‐
vated.
The color depends on the LED state
when component recognition is activated.
-
LEDs of the DM10 diagnostics module
The LEDS installed on the diagnosis module indicate the logic state of the signals present
between the communication partners of the DM10 diagnosis module.
Table 8-5 LEDs of the DM10 diagnostics module
LED Communication partner Meaning: signal 1 / signal 0
H30 -X232/-X32 Control signals from PSA present / not present
H31 -X232/-X32 Control signals from PSA present / not present
H32 -X232/-X32 Control signals from PSA present / not present
Operation
8.5 Fault and system messages
SINAMICS SM150 6SL3845-7NN46-7AA0
Operating Instructions 04/2017 149