Note
It is not necessary to vent the phase module.
Check the water level in the expansion vessel of the re-cooling unit. If necessary, add water.
You can find more detailed information on this in the chapter "Description of components" in
the "Re-cooling unit" section.
9.7.4 Replacing the operator panel
9.7.4.1 Replacing the TP900 operator panel
To replace the operator panel, proceed as follows:
1. Disconnect the cabinet from the power supply.
2. Open the cabinet.
3. Remove the SD card from the data slot.
Figure 9-22 Remove the operator panel.
Maintenance
9.7 Repairs
SINAMICS SM150 6SL3845-7NN46-7AA0
180 Operating Instructions 04/2017