Installing and putting a SINAUT modem into operation
5.4 GPRS/GSM wireless modem MD741-1
Station control system
System Manual, 07/2009, C79000-G8976-C178-07
191
Installation on a 35 mm standard rail
The SINAUT MD741-1 is intended for installation on DIN rails complying with DIN EN 50022.
There is a suitable fastener on the rear of the device.
Table 5- 8 Dimensions of the MD741-1 modem
MD741-1 Dimensions
W x H x D (mm) 45 x 99 x 114
Depth with connected antenna / Ethernet cable (mm) approx. 170
5.4.2 Connecting the MD741-1 to the TIM and antenna
The following figure shows how the GPRS modem MD741-1 is connected to a TIM over its
Ethernet connector (IE) and how the SMA connector is connected to an antenna.
6 4 &
'&9
67$7
/,1.
931
;
6,1$87
0'
$$
s
56
)25/$121/<
;
SET
0'
,(
,(
60$
7,09,(
,(SDWFKFDEOH
$1705DQWHQQD
Figure 5-4 Connecting the MD741-1 to a TIM and an antenna
5.4.3 Prerequisites for operation
To use the MD741-1, the following requirements must be met:
● A subscriber contract with GSM network operator that supports GPRS
● SIM card for enabling GPRS for the user by the network operator