Pre-con󹪝guration of the PCU
A PCU has two Ethernet interfaces with default settings suitable for use with SINUMERIK solution
line:
PCU
Eth 2 Eth 1
Eth 1 is pre-selected as a default DHCP client for connection to a
company network.
Eth 2 is pre-selected as a SINUMERIK DHCP server for connection to
a system network. On Eth 2 the 󹪝xed IP address 192.168.214.241
is pre-selected.
Precon󹪝guration of the NCU
On the X120, the NCU is precon󹪝gured for the SINUMERIK DHCP protocol. The NCU is pre-
selected here as a SINUMERIK DHCP server. On X120, the NCU occupies the 󹪝xed IP address
192.168.214.1 with the subnet mask 255.255.255.0 in its capacity as a DHCP server. The DHCP
server of the NCU assigns IP addresses from the range 192.168.214.10 – 192.168.214.239 to
the DHCP clients. The behavior of the NCU on X120 cannot be modi󹪝ed.
Restricting the available address band that is managed by the DHCP server of the NCU frees
up IP addresses 192.168.214.2 to 192.168.214.9 as well as addresses 192.168.214.241 to
192.168.214.254 for network nodes with 󹪝xed IP addresses.
1&8
;
;;
The NCU has three Ethernet connections:
- X120 to connect to the system network with an active DHCP server
(Eth 0)
- X130 to connect to the company network as a default DHCP client
(Eth 1)
- X127 as a service connection with an active DHCP server (Ibn 0)
On X130, the NCU is set as a default DHCP client for the address reference from a company
network. The IP address received here is speci󹪝ed by the DHCP server from the company
network.
On X127, an NCU is a standard DHCP server (in contrast to the SINUMERIK DHCP
server). On X127, the NCU has the 󹪝xed IP address 192.168.215.1 with the subnet mask
255.255.255.224). The IP addresses 192.168.215.2 – 192.168.215.23 are dynamically
assigned to the DHCP clients. The range 192.168.215.24 - 192.168.215.30 is reserved, and
can be used by stations on the network with a 󹪝xed IP address, e.g. by a modem.
Reserved IP addresses for NCU and PCU
The following defaults apply on delivery:
Connection to the system network with subnet mask 255.255.255.0:
IP address Network station Remark
192.168.214.1 NCU on X120 Default
192.168.214.2 – 9 For additional NCUs with a 󹪝xed IP address on the
system network
Unassigned
General information and networking
4.3Networking
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA 41

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals