4.3.3.3 Networks with NCU connection to the company network
Con󹪝guration 3: NCU and TCU
Description
6ZLWFK
1&8
7&8
6\VWHPQHWZRUN
&RPSDQ\QHWZRUN
;
;
The TCU is connected to the NCU (directly) using a crossed Ethernet cable. On X130, the
NCU is connected to a switch to the company network with a straight cable.
As in con󹪝guration 1, there is a direct Ethernet connection between a TCU and X120 of the
NCU. NCU and TCU are suitably precon󹪝gured with IP addresses. The IP addresses used here
are not signi󹪝cant for further operation.
IP con󹪝guration: DHCP server on the company network
On X130, the NCU is set to the address reference via DHCP. If the company network has a DHCP
server that provides the NCU with an IP address (IP con󹪝guration), the NCU is integrated into the
company network.
Depending on the infrastructure available or the level of network administration of the
company network, the following network parameters must be set for the NCU on X130:
Computer name on the company network
Address of a DNS server
Address of a gateway (default router)
The IP address of the NCU to this connection is also assigned via network administration.
General information and networking
4.3Networking
Handheld Terminal HT 8
80 Equipment Manual, 02/2024, A5E52918633B AA

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals