Type of condition Permissible range/class
Ambient temperature -20°C ... +55°C
Biological environmental condi‐
tions
1B1
1)
Chemically active environmental
conditions
1C2
2)
Mechanical environmental condi‐
tions
Class 1M2 according to EN 60721-3-1, in product packaging
3)
Maximum permissible tempera‐
ture change
30 k/h
Relative humidity (without conden‐
sation)
5 to 95%
Precipitation, rain Not permissible
Water other than rain Not permissible
4)
Height Max. 4,000 m above sea level
Condensation, splash water,
icing, salt spray
Not permissible
4)
1) Mold growth, slime, animal pests, rodents, termites and other animal vermin are not permissible.
2) In marine- and weather-resistant transport packaging (container).
3) Product packaging (storage packaging) is an individual packaging for storage and does not satisfy the
requirements for transport. As a consequence, product packaging is therefore not suitable for shipping.
4) For storage in the product packaging.
Note
Remove the transport protective foil and packaging material before installing the components.
4.1.2.2 Operating conditions
The components of the SINUMERIK 840D sl system are intended for a weatherproof, 󹪝xed
location. The documented
environmental conditions apply to the climate in the immediate vicinity of the units and to the
entry of the cooling air. They exceed the requirements according to EN 60204-1, EN 61800-2,
EN 61131-2 and IEC 62477-1.
NOTICE
Damage to components by coolants and lubricants
The SINUMERIK operator components have been designed for industrial use, particularly on
machine tools and production machines. This also takes into account the use of commercially
available coolants and lubricants. The use of aggressive compounds and additives can damage
components and result in their failure.
Contact between the operator components and coolants and lubricants should be avoided as
far as possible, as resistance to all coolants and lubricants cannot be guaranteed.
General information and networking
4.1Application planning
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA 27

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals