If the company network o󹪜ers a low level of administration (in the worst case scenario the
network has only one DHCP server that assigns the addresses from a prede󹪝ned address
range) the NCU receives an IP address that is initially unknown.
Con󹪝guration 4: NCU and PCU with direct OP
Description
1&83&8
6\VWHPQHWZRUN
&RPSDQ\QHWZRUN
6ZLWFK
;
(WK
;
(WK
The NCU and PCU are connected via a crossed Ethernet cable.
On X120, the NCU occupies the 󹪝xed IP address 192.168.214.1 in its capacity as a DHCP
server (not used in this con󹪝guration). For this Eth 2 con󹪝guration, the PCU is assigned
a 󹪝xed IP address in the range 192.168.214.241 – 192.168.214.249 with a subnet mask
255.255.255.0 .
The observations made for con󹪝guration 3 also apply here in relation to the connection to
the company network. The connection to a switch on the company network is made via a
non-crossed Ethernet cable.
General information and networking
4.3Networking
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA 81

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals