=1 No stop of the retraction motion in case of an axial feedstop or CP-SW limit stop
or stop by an OEM application
Bit1: Feed disable in channel NC/PLC interface signal DB3200 DBX6.0 (Feed stop)
=0 Stop of the retraction motion in case of a feed stop in the channel
=1 No stop of the retraction motion in case of a feed stop in the channel
22000 AUXFU_ASSIGN_GROUP C04 H2, S1
- Auxiliary function group DWORD PowerOn
-
- 64 5, 5, 1, 1, 1, 1, 1, 1, 1,
1, 1, 1, 1, 1, 1, 1, 1, 1,
1, 1,1, 1,
1 168 2/2 M
Description: See MD22010 $MC_AUXFU_ASSIGN_TYPE [n] (auxiliary function type)
22010 AUXFU_ASSIGN_TYPE C04 H2, S1
- Auxiliary function type STRING PowerOn
-
- 64 M, M, , , , , , , , , , , , , , - - 2/2 M
Description: Machine data
AUXFU_ASSIGN_TYPE[n] (auxiliary function type),
AUXFU_ASSIGN_EXTENSION[n] (auxiliary function extension),
AUXFU_ASSIGN_VALUE[n] (auxiliary function value) and
AUXFU_ASSIGN_GROUP[n] (auxiliary function group)
assign an auxiliary function type (M,S,H,T,F,D,DL), the associated extension and the
auxiliary function value to an auxiliary function group.
Example:
M0 = 100 => Group 5 (corr. M100)
Auxiliary function type M
Auxiliary function extension 0
Auxiliary function value 100
Auxiliary function group 5
MD22010 $MC_AUXFU_ASSIGN_TYPE[0] = "M"
MD22020 $MC_AUXFU_ASSIGN_EXTENSION[0] = 0
MD22030 $MC_AUXFU_ASSIGN_VALUE[0] = 100
MD22040 $MC_AUXFU_ASSIGN_GROUP[0] = 5 ; (5th group)
M00, M01, M02, M17 and M30 are assigned to group 1 as default.
M3, M4, M5 and M70 of the master spindle are assigned to group 2 as default.
The S functions of the master spindle are assigned to group 3 as default.
The four machine data for assigning an auxiliary function to an auxiliary function
group must always be given the same index [n].
Special cases:
If the value of an auxiliary function is less than 0, all auxiliary functions of this
type and extension are assigned to one group.
Example:
S2 = -1 => group 9
(all S values of the 2nd spindle are assigned to group 9)
Note:
Only one auxiliary function from a group may be programmed in each block, otherwise
alarm 14760 is output.