22621 ENABLE_START_MODE_MASK_PRT EXP, C03 M3, K1
- Enables MD22620 $MC_START_MODE_MASK_PRT DWORD Reset
-
- - 0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0...
0 0x1 1/1 M
Description: MD22620 $MC_START_MODE_MASK_PRT is activated via MD22621
$MC_ENABLE_START_MODE_MASK_PRT.
If MD22621 $MC_ENABLE_START_MODE_MASK_PRT is in its initial setting, MD22620
$MC_START_MODE_MASK_PRT is inactive.
Bit0 = 1:
If a "search via program test" (English abbr. SERUPRO) is started from RESET (PI
service _N_FINDBL mode paramter == 5), MD22620 $MC_START_MODE_MASK_PRT replaces
MD20112 $MC_START_MODE_MASK.
This method can be used to set a start behavior differing from PLC start when the
search is started.
22700 TRACE_STARTTRACE_EVENT EXP, C06 -
- Diagnostic data rec. starts with event
TRACE_STARTTRACE_EVENT.
STRING PowerOn
NBUP
- - - - - 1/1 M
Description: The machine data is intended for diagnostics.
The recording of the diagnostic data does not start until the event
(TRACE_STARTTRACE_EVENT) has occurred at the trace point
(TRACE_STARTTRACE_TRACEPOINT) and in the correct step (TRACE_STARTTRACE_STEP)!
The machine data is additionally activated using the Cancel alarm key.
22702 TRACE_STARTTRACE_STEP EXP, C06 -
- Conditions for start of trace recording STRING PowerOn
NBUP
- 2 ,, , , , , , , , , , , , , , ... - - 1/1 M
Description: The machine data is only intended for diagnostic use.
See TRACE_STARTTRACE_EVENT
For TRACE_STARTTRACE_EVENT BLOCK_CHANGE the string TRACE_STARTTRACE_STEP is
interpreted as a file name and block number!
For BSEVENTTYPE_SETALARM the string is interpreted as an alarm number.
The machine data can be additionally activated using the Cancel alarm key.
22704 TRACE_STOPTRACE_EVENT EXP, C06 -
- Conditions for stop of trace recording STRING PowerOn
NBUP
- - CLEARCANCELALAR
M_M,
CLEARCANCELALAR
M_M,
CLEARCANCELALAR
M_M, CLEA...
- - 1/1 M
Description: The machine data is only intended for diagnostics.
The recording of the diagnostic data ends when the event (TRACE_STOPTRACE_EVENT) has
occurred at the trace point (TRACE_STOPTRACE_TRACEPOINT) and in the correct step
(TRACE_STOPTRACE_STEP)!
Machine data
3.3 Channel-specific machine data
Parameter Manual