After reaching the stop condition, the previously recorded diagnostic data is stored
in a file "NCSCTRyy.MPF" or for NCU-LINK in "NCxxTRyy.MPF" in the MPF directory.
The machine data is additionally activated using the Cancel alarm key.
22706 TRACE_STOPTRACE_STEP EXP, C06 -
- CommandSequenzStep with which the recording ends STRING PowerOn
NBUP
- 2 , , , , , , , , , , , , , , , ... - - 1/1 M
Description: The machine data is only intended for diagnostics.
The machine data can be additionally activated using the Cancel alarm key.
22708 TRACE_SCOPE_MASK EXP, C06 -
- Selects the contents of the trace file STRING PowerOn
NBUP
- - - - - 1/1 M
Description: The machine data is only intended for diagnostics purposes.
Specific trace contents are selected with the MD data.
The entry SETALARM records the alarm environment and the block change in the main run
is also logged by means of BLOCK_CHANGE.
The machine data is additionally activated using the Cancel alarm key.
22710 TRACE_VARIABLE_NAME - -
- Definition of trace data STRING PowerOn
NBUP
- 10 BL_NR, TR_POINT,
EV_TYPE, EV_SRC,
CS_ASTEP,, BL_NR,
TR_POINT, EV...
- - 1/1 M
Description: The machine data is only intended for diagnostic purposes.
The MD datum defines which data are recorded in the trace file.
22712 TRACE_VARIABLE_INDEX EXP, C06 -
- Index for trace recording data DWORD PowerOn
NBUP
- 10 0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0,
0x0,...
0 0xFFFF 1/1 M
Description: The machine data is only intended for diagnostic use.
The MD data, together with TRACE_VARIABLE_NAME, determines which data are recorded in
the trace file.
It enables access to an array element.
E.g. use as an axis index when accessing axis data.
22714 MM_TRACE_DATA_FUNCTION EXP, C02, C06 -
- Activating diagnostics DWORD PowerOn
NBUP
- - 0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0...
0 0xFFFFFF 1/1 M
Description: The machine data is only intended for diagnostic purposes.
Activating diagnostics
Machine data
3.3 Channel-specific machine data
Parameter Manual