23 Recording if computing time is given away in the preprocessing (only active when
bit 0 is set).
22910 WEIGHTING_FACTOR_FOR_SCALE EXP, C01, C11 -
- Input resolution for scaling factor BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2 M
Description: Definition of the unit for the scaling factor P and for the axial scaling factors I,
J, K.
Meaning:
0 Scale factor in 0.001
1 Scale factor in 0.00001
Related to:
SD43120 $SA_DEFAULT_SCALE_FACTOR_AXIS,
SD42140 $SC_DEFAULT_SCALE_FACTOR_P
22914 AXES_SCALE_ENABLE EXP, C01, C11 -
- Activation for axial scaling factor ( G51 ) BOOLEAN PowerOn
-
- - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 2/2 M
Description: This MD enables axial scaling.
Meaning:
0: Axial scaling not possible
1: Axial scaling possible -> MD DEFAULT_SCALE_FACTOR_AXIS is active
Related to:
SD43120 $SA_DEFAULT_SCALE_FACTOR_AXIS
22920 EXTERN_FIXED_FEEDRATE_F1_ON EXP, C01, C11 -
- Activation of fixed feedrates F1 - F9 BOOLEAN PowerOn
-
808d-me42 - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 0/0 S
808d-me62 - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 0/0 S
808d-te42 - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 0/0 S
808d-te62 - FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE,
FALSE, FALSE...
0 - 0/0 S
Machine data
3.3 Channel-specific machine data
Parameter Manual