Description: Restriction of working area in front of/behind pole or no restriction, i.e. traversal
through pole.
The assigned values have the following meanings:
1: Working area of linear axis for positions >=0,
(if tool length compensation parallel to linear axis equals 0)
2: Working area of linear axis for positions <=0,
(if tool length compensation parallel to linear axis equals 0)
0: No restriction of working area. Traversal through pole.
24970 TRANSMIT_BASE_TOOL_2 C07 M1
mm Vector of base tool for 2nd TRANSMIT transformation DOUBLE NEW CONF
-
808d-me42 3 0.0, 0.0 , 0.0, 0.0, 0.0 ,
0.0, 0.0, 0.0 , 0.0, 0.0,
0.0 , 0.0, ...
- - 1/1 M
808d-me62 3 0.0, 0.0 , 0.0, 0.0, 0.0 ,
0.0, 0.0, 0.0 , 0.0, 0.0,
0.0 , 0.0, ...
- - 1/1 M
808d-te42 3 0.0, 0.0 , 0.0, 0.0, 0.0 ,
0.0, 0.0, 0.0 , 0.0, 0.0,
0.0 , 0.0, ...
- - 1/1 M
808d-te62 3 0.0, 0.0 , 0.0, 0.0, 0.0 ,
0.0, 0.0, 0.0 , 0.0, 0.0,
0.0 , 0.0, ...
- - 1/1 M
808d-mte40 3 0.0, 0.0 , 0.0, 0.0, 0.0 ,
0.0, 0.0, 0.0 , 0.0, 0.0,
0.0 , 0.0, ...
- - 7/7 U
808d-mte60 3 0.0, 0.0 , 0.0, 0.0, 0.0 ,
0.0, 0.0, 0.0 , 0.0, 0.0,
0.0 , 0.0, ...
- - 7/7 U
Description: Indicates a basic offset of the tools zero for the 2nd TRANSMIT transformation. The
offset is referenced to the geometry axes valid when TRANSMIT is active. The basic
offset is included with and without selection of the tool length compensation.
Programmed length corrections have an additive effect with respect to the basic tool.
The index i takes the values 0, 1, 2 for the 1st to 3rd geometry axes.
Related to:
MD24920 $MC_TRANSMIT_BASE_TOOL_1
27100 ABSBLOCK_FUNCTION_MASK N01 K1, P1
- Parameterize basic blocks with absolute values DWORD PowerOn
-
- - 0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0...
0 0x1 2/2 M
Description: Parameterization of the "basic blocks with absolute values" function
Bit 0 = 1 :
The position values of the transverse axis are always displayed as diameter values.
Transverse axes can be applied using MD20100 $MC_DIAMETER_AX_DEF or MD30460
$MA_BASE_FUNCTION_MASK, bit 2.
Machine data
3.3 Channel-specific machine data
Parameter Manual
204 List Manual, 01/2017