Description: Default value for path feedrate, This setting data is evaluated when the part program
starts taking into account the feedrate type active at this time (see MD20150
$MC_GCODE_RESET_VALUES and MD20154 $MC_EXTERN_GCODE_RESET_VALUES).
42120 APPROACH_FEED - -
mm/min Path feedrate in approach blocks DOUBLE Immediately
-
808d-me42 - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 2/2 M
808d-me62 - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 2/2 M
808d-te42 - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 2/2 M
808d-te62 - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 2/2 M
808d-mte40 - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 7/7 U
808d-mte60 - 0., 0., 0., 0., 0., 0., 0.,
0....
0.0 - 7/7 U
Description: Default value for path feedrate in approach blocks (after repos., block search,
SERUPRO etc).
The contents of this settting data are only used when it is non-zero.
It is evaluated like an F word programmed for G94.
42121 AX_ADJUST_FEED - -
mm/min Path feed in adjustment movements DOUBLE Immediately
-
808d-me42 - 0., 0., 0., 0., 0., 0., 0.,
0....
- - 2/2 M
808d-me62 - 0., 0., 0., 0., 0., 0., 0.,
0....
- - 2/2 M
808d-te42 - 0., 0., 0., 0., 0., 0., 0.,
0....
- - 2/2 M
808d-te62 - 0., 0., 0., 0., 0., 0., 0.,
0....
- - 2/2 M
808d-mte40 - 0., 0., 0., 0., 0., 0., 0.,
0....
- - 7/7 U
808d-mte60 - 0., 0., 0., 0., 0., 0., 0.,
0....
- - 7/7 U
Description: Default value for the path feed in adjustment movements of tangential axes on
activation of a tangential axis coupling during or after block search.
The content of this setting data is only used if it is not equal to zero and bit7 = 0
of MD $MN_SEARCH_RUN_MODE is set.
It is evaluated as an F-word programmed in G94.
42122 OVR_RAPID_FACTOR - MD12050
$MN_OVR_FACTOR_RAPID_T
RA, $AC_OVR
% Add. rapid traverse override can be specified through operation DOUBLE Immediately
-
- - 100., 100., 100., 100.,
100., 100., 100., 100....
0.0 - 7/7 U
NC setting data
Parameter Manual
330 List Manual, 01/2017