If one uses the prog. event for search and if the NCK is at alarm 10208 then a change
of SERUPRO_SYNC_MASK is not active unless one sets a new REPOS.
SERUPRO_SYNC_MASK == 0 A block is NOT inserted.
Note:
If the bit for the current channel is not set in SD42125 $SC_SERUPRO_SYNC_MASK then a
block is NOT inserted.
Example:
If SD42125 $SC_SERUPRO_SYNC_MASK= 0xE is programmed in channel 1, then a block is NOT
inserted.
This assignment is reserved for a future function!
42140 DEFAULT_SCALE_FACTOR_P - FBFA
- Default scaling factor for address P DWORD Immediately
-
- - 1, 1, 1, 1, 1, 1, 1, 1... - - 7/7 U
Description: The value in this machine data is active if no scaling factor P has been programmed in
the block.
Related to:
WEIGHTING_FACTOR_FOR_SCALE
42150 DEFAULT_ROT_FACTOR_R - -
- Default rotation factor for address R DOUBLE Immediately
-
- - 0., 0., 0., 0., 0., 0., 0.,
0....
- - 7/7 U
Description: The value in this machine data is active if no factor for rotation R is programmed in
the block.
42160 EXTERN_FIXED_FEEDRATE_F1_F9 - FBFA
- Fixed feedrates F1 - F9 DOUBLE Immediately
-
808d-me42 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 0/0 S
808d-me62 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 0/0 S
808d-te42 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 0/0 S
808d-te62 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 0/0 S
808d-mte40 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 7/7 U
808d-mte60 10 0., 0., 0., 0., 0., 0., 0.,
0., 0., 0., 0., 0., 0., 0.,
0., 0., ...
0.0 - 7/7 U
Description: Fixed feedrate values for programming with F1 - F9. If the machine data
$MC_FEEDRATE_F1_F9_ON = TRUE is set with the programming of F1 - F9, the feedrate
values are read from SD42160 $SC_EXTERN_FIXED_FEEDRATE_F1_F9[0] - SD42160
$SC_EXTERN_FIXED_FEEDRATE_F1_F9[8], and activated as the machining feedrate.
NC setting data
Parameter Manual
332 List Manual, 01/2017