SD43230 $SA_SPIND_MAX_VELO_LIMS (programmed spindle speed limit with G96/961)
MD10709 $MN_PROG_SD_POWERON_INIT_TAB
MD10710 $MN_PROG_SD_RESET_SAVE_TAB
43235 SPIND_USER_VELO_LIMIT A06 S1, Z1
rev/min Maximum spindle speed DOUBLE Immediately
-
- - 1.0e+8 0.0 - 7/7 U
Description: The user can enter a maximum spindle speed.
The NCK limits an excessive spindle setpoint speed to this value. The SD is effective
immediately.
Corresponds with:
MD35100 $MA_SPIND_VELO_LIMIT (maximum spindle speed)
MD35110 $MA_GEAR_STEP_MAX_VELO (maxmum speed for gear stage change)
43240 M19_SPOS , A12 S1
degrees Spindle position for spindle positioning with M19. DOUBLE Immediately
-
- - 0.0 -10000000.0 10000000.0 7/7 U
Description: Spindle position in [ DEGREES ] for spindle positioning with M19.
The position approach mode is defined in SD43250 $SA_M19_SPOSMODE.
Default positions must lie in the range 0 <= pos < MD30330 $MA_MODULO_RANGE.
Path defaults (SD43250 $SA_M19_SPOSMODE = 2) can be positive or negative and are only
limited by the input format.
43250 M19_SPOSMODE , A12 S1
- Spindle position approach mode for spindle positioning with M19. DWORD Immediately
-
- - 0 0 5 7/7 U
Description: Spindle position approach mode for spindle positioning with M19.
In which signify:
0: DC (default) approach position on the shortest path.
1: AC approach position normally.
2: IC approach incrementally (as path), sign gives the traversing direction
3: DC approach position on the shortest path.
4: ACP approach position from the positive direction.
5: ACN approach position from the negative direction.
43300 ASSIGN_FEED_PER_REV_SOURCE - V1, P2, S1
- Revolutional feedrate for positioning axes/spindles DWORD Immediately
CTEQ
- - 0 -3 31 1/1 M
Description: 0= No revolutional feedrate is active.
>0= Machine axis index of the rotary axis/spindle, from which the revolutional
feedrate is derived.
-1= The revolutional feedrate is derived from the master spindle of the channel in
which the axis/spindle is active
-3= The revolutional feedrate is derived from the master spindle of the channel in
which the axis/spindle is active. No revolutional feedrate is active if the master
spindle is at a standstill.
NC setting data
Parameter Manual
List Manual, 01/2017 365