EasyManua.ls Logo

Siemens SINUMERIK 808D - Page 62

Siemens SINUMERIK 808D
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11161 ACCESS_EXEC_CMA N01 -
- Execution right for /_N_CMA_DIR BYTE PowerOn
-
- - 7 0 7 2/2 M
Description: Execution right assigned to the programs stored in directory /_N_CMA_DIR :
Value 0: Siemens password
Value 1: Machine OEM password
Value 2: Password of setup engineer, service
Value 3: End user password
Value 4: Keyswitch position 3
Value 5: Keyswitch position 2
Value 6: Keyswitch position 1
Value 7: Keyswitch position 0
Machine data can only be written with values 0 and 1, and with the corresponding
password also active.
11162 ACCESS_EXEC_CUS N01 -
- Execution right for /_N_CUS_DIR BYTE PowerOn
-
- - 7 0 7 3/3 U
Description: Execution right assigned to the programs stored in directory /_N_CUS_DIR :
Value 0: Siemens password
Value 1: Machine OEM password
Value 2: Password of setup engineer, service
Value 3: End user password
Value 4: Keyswitch position 3
Value 5: Keyswitch position 2
Value 6: Keyswitch position 1
Value 7: Keyswitch position 0
Machine data can only be written with values 0, 1 and 2, and with the corresponding
password also active.
11165 ACCESS_WRITE_CST N01 -
- Write protection for directory /_N_CST_DIR DWORD PowerOn
-
- - -1 -1 7 2/2 M
Description: Set write protection for cycle directory /_N_CST_DIR:
Assigned to the programs:
Value -1: Keep the value currently set
Value 0: Siemens password
Value 1: Machine OEM password
Value 2: Password of setup engineer, service
Value 3: End user password
Value 4: Keyswitch position 3
Value 5: Keyswitch position 2
Value 6: Keyswitch position 1
Value 7: Keyswitch position 0
Machine data
3.2 General machine data
Parameter Manual
62 List Manual, 01/2017

Table of Contents

Other manuals for Siemens SINUMERIK 808D

Related product manuals