808d-te42 16 -1, -1, -1, -1, -1, -1, -1,
-1...
-1 255 ReadOnly M
808d-te62 16 -1, -1, -1, -1, -1, -1, -1,
-1...
-1 255 1/1 M
808d-mte40 16 -1, -1, -1, -1, -1, -1, -1,
-1...
-1 255 1/1 M
808d-mte60 16 -1, -1, -1, -1, -1, -1, -1,
-1...
-1 255 1/1 M
Description: The PLC input/output image of the stations with these logical addresses
is not connected to the real I/Os
13080 DRIVE_TYPE_DP EXP G2
- PROFIBUS/PROFINET drive type BYTE PowerOn
-
808d-me42 31 0, 0, 0, 0, 0, 0, 0, 0... 0 5 ReadOnly M
808d-me62 31 0, 0, 0, 0, 0, 0, 0, 0... 0 5 ReadOnly M
808d-te42 31 0, 0, 0, 0, 0, 0, 0, 0... 0 5 ReadOnly M
808d-te62 31 0, 0, 0, 0, 0, 0, 0, 0... 0 5 ReadOnly M
808d-mte40 31 0, 0, 0, 0, 0, 0, 0, 0... 0 5 7/2 M
808d-mte60 31 0, 0, 0, 0, 0, 0, 0, 0... 0 5 7/2 M
Description: MD is relevant to PROFIdrive drives at the PROFIBUS/PROFINET:
Drive type:
0: No drive or drive type unknown (default),
software-internally treated as:
1: FDD drive (SRM: Synchronous rotary drive)
2: MSD drive (ARM: Asynchronous rotary drive)
3: Linear drive
4: Analog drive (no automatic entry)
5: Hydraulic drive
Note:
In general, the drive type is entered automatically with Siemens drives as soon as the
drives start operating.
With non-Siemens drives (at least with linear drives), the value must be entered
manually if automatic drive recognition is not possible.
13110 PROFIBUS_TRACE_ADDRESS EXP -
- PROFIBUS/PROFINET trace of I/O slots DWORD NEW CONF
-
808d-me42 14 0, 0, 0, 0, 0, 0, 0, 0... 0 - 0/0 S
808d-me62 14 0, 0, 0, 0, 0, 0, 0, 0... 0 - 1/1 M
808d-te42 14 0, 0, 0, 0, 0, 0, 0, 0... 0 - 0/0 S
808d-te62 14 0, 0, 0, 0, 0, 0, 0, 0... 0 - 1/1 M
808d-mte40 14 0, 0, 0, 0, 0, 0, 0, 0... 0 - 2/2 M
808d-mte60 14 0, 0, 0, 0, 0, 0, 0, 0... 0 - 2/2 M
Description: For PROFIBUS/PROFINET only:
Logical I/O address that is to be recorded.
Machine data
3.2 General machine data
Parameter Manual
80 List Manual, 01/2017