EasyManuals Logo

Siemens SINUMERIK 840D Installation And Startup Guide

Siemens SINUMERIK 840D
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #273 background imageLoading...
Page #273 background image
11
03.96
11.5 Several SW versions on one MMC 103 (SW 5.2 and higher)
11-273
Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) 04.00 Edition
If you wish to delete the image of a software version from the Images directory,
proceed as follows:
1. Switch on the control and select start-up mode (press key 6 when DOS/Win-
dows screen appears),
2. Select menu 7: Backup/Restore
3. Enter password
4. Select menu 4 Partitions Backup/Restore
5. In order to delete the image of a software version, select menu
option 4: Delete Image
6. Select the software version of your choice from the displayed list.
7. The deleted software version is removed from the Images directory and
therefore no longer listed when you select menu option 3: Partitions Re-
store.
Two versions of the Norton Ghost software are available on the control in V 5.2
and higher:
S Norton Ghost Version 5.1b (standard)
S Norton Ghost Version 6.01
The data format has been changed in Norton Ghost version 5.1c and later
which means that earlier Norton Ghost versions, i.e. < V 5.1c, cannot read the
new data format.
If the current version 6.01 is needed (because, for example, a later version is
installed on the PG/PC), it can be activated via the Service menu:
1. Switch on the control and select start-up mode (press key 6 when DOS/Win-
dows screen appears),
2. Select menu 7: Backup/Restore
3. Enter password
4. Select option Switch to other version of GHOST. The active version of Nor-
ton Ghost is displayed at the top of the screen.
When the software is transferred via the parallel interface LPT, it is not possible
to mix the Norton Ghost software with old (< V 5.1c) and new (>V 5.1 b) ver-
sions. It must be ensured that a compatible data format is transferred via this
interface:
S Norton Ghost V5 up to and including V5.1b or
S Norton Ghost V5.1c up to and including V6.x
Delete a SW
version from the
Images directory
SW Norton Ghost
Transfer via
parallel interface
LPT
11 Data Backup
04.00

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB

Related product manuals