Feed motors, main spindle motors and direct-drive motors in synchronous and asynchronous
design:
Feed motors: 1FT, 1FK
Main spindle motors: 1PH, 1FE, 2SP1
Direct-drive motors: 1FN3, 1FW6
Limited operation of I/O devices and NCK drives
The I/O connection options that are supported are listed in the table.
More information is also provided in the Commissioning Manual "SINUMERIK ONE Steps
when Con󹪝guring and Commissioning".
DP1 (X126)
Interface
DP Integrated
Interface
PN1 (X150)
Interface
PN2 (X160)
Interface
PLC
I/O (e.g. ET200)
X --- X X
NCK
I/O (e.g. ET200)
X
1
--- X ---
Isochronous PLC
I/O (e.g. ET200)
X --- X ---
Isochronous NCK
I/O (e.g. ET200)
X
1 2
--- X ---
Isochronous PLC +
NCK
I/O at the same in‐
terface
X
1 2
--- X ---
Isochronous NCK
drives
--- X X ---
Isochronous NCK
drives + isochro‐
nous PLC I/O at the
same interface
--- --- X ---
Isochronous PLC
Drives (S7-Mo‐
tion)
X --- X ---
1: from NCU-SW 6.14
2: I/O devices isochronous to DP1, but NCK and DP1 not isochronous.
Note
A speci󹪝c software release is required. More detailed information can be found in the
corresponding SIOS article for the associated software release.
System overview
3.2System con󹪝guration
NCU 1750
Equipment Manual, 10/2023, A5E45627807B AH 25

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0 and is the answer not in the manual?

Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0 Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE 6FC5317-5AA00-0AA0
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals