1 2 3 4 5 6 7 8 9 10 Default device name
o o o o on on on o pp72x48pn112
x x x x x x x x "
on on on on o o o o pp72x48pn15
o on on on o o o o pp72x48pn14
on o on on o o o o pp72x48pn13
o o on on o o o o pp72x48pn12
on on o on o o o o pp72x48pn11
o on o on o o o o pp72x48pn10
on o o on o o o o pp72x48pn9
o o o on o o o o pp72x48pn8
on on on o o o o o pp72x48pn7
o on on o o o o o pp72x48pn6
on o on o o o o o pp72x48pn5
o o on o o o o o pp72x48pn4
on on o o o o o o pp72x48pn3
o on o o o o o o pp72x48pn2
on o o o o o o o pp72x48pn1
o o o o o o o o pp72x48pn
Note
A newly set PROFINET address will only come into eect after power OFF/ON.
12.2.3.4 X111, X222 and X333 digital inputs/outputs
X111, X222 and X333 pin assignment
Cable specication
• Connectors: 50-pin ribbon cable connectors
• 50-pin insulation displacement connectors with cable grip, ribbon cables and terminal
converters
are required for connecting digital inputs and outputs.
• The required connecting cables (ribbon cables) must be provided by the user
.
• Max. cable length: 30 m
Connectable components
12.2PP 72/48D PN and PP 72/48D 2/2A PN
NCU 1750