Technical data
11
Table 11-1 Safety-related data
Protection class III
Degree of protection Open type (open equipment)
1)
Approvals CE, cULus, RCM, KC, EAC, UKCA
Declarations of conformity Directive 2004/108/EC (EMC)
Directive 2006/42/EC (machinery directive)
Directive 2011/65/EU (RoHS)
Directive 2011/65/EU (RoHS), supplemented by: Delegated Directive
(EU) 2015/8/63 (document 32015L0863)
Pollution degree 2
Cooling Open-circuit ventilation
Mounting position Vertical
1) Open equipment according to UL61010
Note
Customers must ensure that the product, with the external re protection enclosure to be
attached by customers, meets the requirements for re protection of the material according to
UL 94 V-1 and the mechanical stability / re protection requirements / touch protection according
to UL61010.
Table 11-2 Electrical and mechanical data
6FC5317-5AA00-0AA0 6FC5317-5AA00-0AA1
SIMATIC S7 - integra‐
ted
PLC 1500
Overvoltage category Secondary circuit supplied from primary circuits up to Cat.II, 300VAC
2)
Input voltage
3)
24V DC
Power consumption,
max.
357.5W 306W
Power loss, typ. 44.76W 27W
NCU 1750
Equipment Manual, 10/2023, A5E45627807B AH 97