EasyManuals Logo

Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0 User Manual

Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
5.1.3 EMC limit values in South Korea
The EMC limit values to be observed for Korea correspond to the limit values of the EMC
product standard for variable-speed electric drives EN61800-3 of categoryC2 or the limit
value classA, Group1 according to EN55011. By implementing appropriate additional
measures, the limit values according to categoryC2 or limit value classA, Group1, are
observed. Further, additional measures may be required, for instance, using an additional
radio interference suppression 󹪝lter (EMC 󹪝lter).
The measures for EMC-compliant design of the system are described in detail in this manual
respectively in the Installation Guideline EMC.
Please note that the 󹪝nal statement on compliance with the standard is given by the
respective label attached to the individual unit.
5.1.4 EMF assessments for 24 V components
The 24 V components, e.g. control systems (NCU, MCU, PPU), IPCs, ITCs, IFPs, handheld units
and machine control panels do not generate any appreciable electromagnetic 󹪝elds.
No minimum clearance has to be maintained for 24V components.
The EC Declaration of Conformity for the EMC Directive can be found on the Internet at the
following address (
https://support.industry.siemens.com/cs/https://
support.industry.siemens.com/cs/ww/de/ps/14604/certww/en/ps/13231/cert).
5.2 Climatic and mechanical environmental conditions
5.2.1 Shipping and storage conditions
The components of the SINUMERIK ONE system exceed the requirements according to
EN61800‑2 with regard to shipping and storage conditions.
The following data applies under the following conditions:
Long-term storage in the transport and product packaging:
At weather-protected locations that have continuous contact with outside air through
openings.
Transport in the transport packaging:
In unventilated containers under conditions not protected from weather e󹪜ects.
In the “cold" in accordance with outside air.
Air transport in the air-conditioned cargo hold.
Application planning
5.2Climatic and mechanical environmental conditions
NCU 1750
Equipment Manual, 10/2023, A5E45627807B AH 47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0 and is the answer not in the manual?

Siemens SINUMERIK ONE 6FC5317-5AA00-0AA0 Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE 6FC5317-5AA00-0AA0
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals