Glossary
626
7UT613/63x Manual
C53000-G1176-C160-2
image. The current process state can also be sampled after a data loss by means of
a GI.
GOOSE message GOOSE messages (Generic Object Oriented Substation Event) are data pakets which
are transferred event-controlled via the Ethernet communication system. They serve
for direct information exchange among the relays. This mechanism implements cross-
communication between bay units.
GPS Global Positioning System. Satellites with atomic clocks on board orbit the earth twice
a day on different paths in approx. 20,000 km. They transmit signals which also
contain the GPS universal time. The GPS receiver determines its own position from
the signals received. From its position it can derive the delay time of a satellite signal
and thus correct the transmitted GPS universal time.
Hierarchy level Within a structure with higher-level and lower-level objects a hierarchy level is a con-
tainer of equivalent objects.
HV field description The HV project description file contains details of fields which exist in a ModPara-
project. The actual field information of each field is stored in a HV field description file.
Within the HV project description file, each field is allocated such a HV field description
file by a reference to the file name.
HV project descrip-
tion
All the data is exported once the configuration and parameterization of PCUs and sub-
modules using ModPara has been completed. This data is split up into several files.
One file contains details about the fundamental project structure. This also includes,
for example, information detailing which fields exist in this project. This file is called a
HV project description file.
ID Internal double point indication → Double point indication
ID_S Internal double point indication, intermediate position 00 → Double point indication
IEC International Electrotechnical Commission, international standardisation body
IEC address Within an IEC bus a unique IEC address has to be assigned to each SIPROTEC 4
device. A total of 254 IEC addresses are available for each IEC bus.
IEC communication
branch
Within an IEC communication branch the users communicate on the basis of the
IEC60-870-5-103 protocol via an IEC bus.
IEC61850 International communication standard for communication in substations. The objective
of this standard is the interoperability of devices from different manufacturers on the
station bus. An Ethernet network is used for data transfer.
Initialization string An initialization string comprises a range of modem-specific commands. These are
transmitted to the modem within the framework of modem initialization. The com-
mands can, for example, force specific settings for the modem.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7UT63 series and is the answer not in the manual?

Siemens SIPROTEC 7UT63 series Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7UT63 series
CategoryProtection Device
LanguageEnglish

Related product manuals