EasyManua.ls Logo

Siemens SIRIUS 3SK1

Siemens SIRIUS 3SK1
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
13.3 Expansion modules
3SK1 safety relays
Manual, 04/2013, A5E02526190021A/RS-AA/01
237
13.3.2 Input expansions
13.3.2.1 Technical data for input expansion 3SK1220
3SK1220-.....
Insulation voltage rated value V 50
Resistance against shock 10g / 11 ms
Number of sensor inputs 1-channel or 2-channel 1
Type of the safety-related wiring of the inputs single-channel and two-channel
Product feature transverse contact-secure Yes
Safety Integrity Level (SIL) according to IEC 61508 SIL3
SIL claim limit (for a subsystem) according to EN 62061 3
Performance level (PL) according to ISO 13849-1 e
Category according to ISO 13849-1 4
T1 value for proof test interval or service life according to
IEC 61508
a 20
Safety device type according to IEC 61508-2 Type B
Number of outputs as contact-affected switching element
as NC contact for reporting function instantaneous switching
0
as NO contact for reporting function instantaneous switching
0
as NC contact for reporting function delayed switching
0
as NO contact for reporting function delayed switching
0
as NC contact safety-related instantaneous switching
0
as NO contact safety-related instantaneous switching
0
as NC contact safety-related delayed switching
0
as NO contact safety-related delayed switching
0
Stop category according to DIN EN 60204-1
0
Design of the input start input Yes
Design of the electrical connection jumper socket No
Operating cycles maximum 1/h