Setup with the integrated HMI
7.5.2Quick setup level, space, distance
Material type
Used to optimize the device function depending on the type of material and vessel or
application:
Setting Selection Selection Vessel
STRGE Process vessel with agitation
PRCSS Wet well
WTWLL Outside of Plastic Tank
PLSTC Level of open liquid
OPEN Demonstration
LIQUID
DEMO MODE Silo
SILO Buffer, surge bin
BIN Heap, pile
MATERIAL TYPE
SOLID
OPEN Heap profile
Unit
UNITS:
Sets the measuring unit used (default setting in brackets):
• Meter " m" (3 decimal places)
• Centimeter " cm" (1 decimal place)
• Feet " ft
" (3 decimal places)
• Inches " in" (2 decimal places)
Lower calibration point
LOWER CAL PT:
Sets the distance from the transmitter reference point to the lower calibration point:
usually corresponds to the zero point of the process.
Upper calibration point
UPPER CAL PT:
Sets the distance from the transmitter reference point to the upper calibration point:
usually corresponds to the full level.
Confirm
CONFIRM:
Accepts the settings as the last step in the wizard.
SITRANS LR150
Operating Instructions, 08/2020, A5E50352155
37