Setup with the integrated HMI
7.5.3Quick setup volume
6
Level
Figure7.7 Overview quick setup volume
Setting Description Reference point
Volume VOL Volume of the material in
volume unit (related to the level)
Lower calibration point
Material type
Used to optimize the device function depending on the type of material and vessel or
application:
Setting Selection Selection Selection
STRGE Vessel
PRCSS Process vessel with agitation
WTWLL Wet well
PLSTC Outside of Plastic Tank
OPEN Level of open liquid
LIQUID
DEMO MODE Demonstration
SILO Silo
BIN Buffer, surge bin
MATERIAL TYPE
SOLID
OPEN Heap, pile
Unit
UNITS:
Sets the measuring unit used (default setting in brackets):
Meter " m" (3 decimal places)
Centimeter " cm " (1 decimal place)
Feet " ft " (3 decimal places)
Inches " in " (2 decimal places)
Vessel shape
VESSEL SHAPE:
Sets the vessel shape and allows the device to calculate the volume instead of the
level:
Linear vessel (LINR)
Conical vessel bottom (CONIC)
Container with flat sloping bottom (FLAT)
Cylindrical vessel (CYLIN)