4BWEIGHING FUNCTIONS
A maximum value monitor is realized with the following specification:
Activation value > deactivation value
A minimum value monitor is realized with the following specification:
Activation value < deactivation value
The following diagram illustrates the function of limit values 1 and 2.
Figure 5-5 Parameterization of the limit values
5.7.2 DR 21/22 – cut-off weight limit value 1
See: Switch-on weight limit value 1
5.7.3 DR 21/22 – switch-on weight limit value 2
See: Switch-on weight limit value 1
5.7.4 DR 21/22 – cut-off weight limit value 2
See: Switch-on weight limit value 1
5.8 DR 31 Process values channel 1, DR 32 process values channel 2
In data record DR31, the current process values of measurement channel 1 are
displayed. The design of DR32 is identical and the measurement values relate to
measurement channel 2. With the aid of the process values, the current statuses
and data in the scale can be observed.
SIWAREX U 5-37