12BTECHNICAL DATA
13.9 Mechanical requirements and data
Test Standards Test values
Vibration
in operation
IEC 60068-2-6
Test Fc
5 ... 9 Hz: 3.5 mm movement
9 ...150 Hz: 9.8 m/s
2
10 cycles per axis
1 octave / min.
Shock
in operation
IEC 60068-2-27
Test Ea
150 m/s
2
, half sine
Duration: 11 ms
Number: 3 per axis
in neg. and pos. direction
Vibration
during transport
IEC 60068-2-6
Test Fc
5 ... 9 Hz: 3.5 mm movement
9 ...500 Hz: 9.8 m/s
2
10 cycles per axis
1 octave / min.
Shock
during transport
IEC 60068-2-29
Test Eb
250 m/s
2
, half sine
Duration: 6 ms
Number: 1000 per axis
Free fall IEC 68000-2-32
Test Ed
Height of fall:
1 m in transport packaging
0.3 m in product packaging
Table 13-9 Data: Mechanical requirements