Scale parameters and functions
8.21 DR 22 Tolerance parameters
SIWAREX WP251
Manual, 12/2015, A5E37203357A
113
Variable
Note
Data type
Length
(bytes)
RW
De-
fault
Min
Max
Modbus
registers
Behavior in
case of TH1
error
(Page 116)
0: Weighing cycle is
not stopped and is
completed with
"Dosing completed"
1: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again
and the cycle is then
completed with
"Dosing completed"
in any case.
2: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again.
If there is still a tol-
erance error, the
scale goes to Stop
state again. This is
repeated until the
tolerance error is
eliminated (e.g. by
manually adding or
removing material).
USHORT 2 rw 0 0 0 1659