EasyManuals Logo

Siemens SIWAREX WP251 User Manual

Siemens SIWAREX WP251
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
Scale parameters and functions
8.21 DR 22 Tolerance parameters
SIWAREX WP251
Manual, 12/2015, A5E37203357A
113
Variable
Note
Data type
Length
(bytes)
RW
De-
fault
Min
Max
Modbus
registers
Behavior in
case of TH1
error
(Page 116)
0: Weighing cycle is
not stopped and is
completed with
"Dosing completed"
1: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again
and the cycle is then
completed with
"Dosing completed"
in any case.
2: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again.
If there is still a tol-
erance error, the
scale goes to Stop
state again. This is
repeated until the
tolerance error is
eliminated (e.g. by
manually adding or
removing material).
USHORT 2 rw 0 0 0 1659

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP251 and is the answer not in the manual?

Siemens SIWAREX WP251 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP251
CategoryAccessories
LanguageEnglish

Related product manuals