Scale parameters and functions
8.21 DR 22 Tolerance parameters
SIWAREX WP251
114 Manual, 12/2015, A5E37203357A
Variable
Note
Data type
Length
(bytes)
RW
De-
fault
Min
Max
Modbus
registers
Behavior in
case of TL1
error
(Page 116)
0: Weighing cycle is
not stopped and is
completed with
"Dosing completed"
1: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again,
and the cycle is then
completed with
"Dosing completed"
in any case.
2: Weighing cycle is
stopped. User can
use the "Continue"
command to check
the tolerance again.
If there is still a tol-
erance error, the
scale goes to Stop
state again. This is
repeated until the
tolerance error is
eliminated (e.g. by
manually adding or
removing material).
3: Post-dosing with
continuous fine
signal
4: Post-dosing with
pulsing
USHORT 2 rw 0 0 0 1660
Reserve
Reserve
USHORT
2
rw
0
0
0
1661
Pulse duration
for pulse post
dosing
(Page 116)
Fine signal ON dura-
tion when "Post-
dosing with pulsing"
is selected
TIME 4 rw 0 0 0 1662
Number of not
controlled
weighings
(Page 117)
Number of cycles
during which WP251
does not perform a
tolerance check in
AWI continuous
operation (active
only when the previ-
ous dosing was
completed with
'GOOD' tolerance).
USHORT 2 rw 0 0 0 1664

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIWAREX WP251 and is the answer not in the manual?

Siemens SIWAREX WP251 Specifications

General IconGeneral
BrandSiemens
ModelSIWAREX WP251
CategoryAccessories
LanguageEnglish

Related product manuals