Errors and messages
9.6 Operating errors
SIWAREX WP251
Manual, 12/2015, A5E37203357A
169
6056 Memory command
6056 Trace, logging or logbook command was rejected. Additional
information contains details.
, because a fault is present
4501 , because no standstill occurred
, because module is already waiting for standstill
, because write protection active
, because weight is outside the permissible weighing range
, because trace memory full
, because log memory full
, because memory task busy
Requested data record is unknown.
7051 Parameter input not
7051 A parameter input is currently not possible. Additional information
, because service mode is not active
, because write protection active
, because password incorrect
7052 Parameter is write
protected and cannot be
changed
7052 A parameter input is currently not possible due to active write
protection. Additional information contains details about the pa-
rameter involved.
Parameter
Parameter ID of the parameter involved
7053 Error in calibration
7053 Additional information indicates an implausible parameter in DR 3
Parameter
Parameter ID of the affected parameter in DR 3
, because service mode is not active
, because increment between calibration digits is too small
, because order of calibration points is incorrect
, because calibration weight 0
, because falling characteristic curve not allowed by OIML
, because mixed characteristic curve not allowed
, because weighing range max - min error
, because resolution not permitted
, because OIML and 3000d requirements violated
7054 Parameter error DR 5
Additional information indicates an implausible parameter in DR 5
Parameter
Parameter ID of the affected parameter in DR 5