Figure 48 the additional Audible Driver Supply Kit should fitted in the position allocated to the
Loop Termination PCB LT5. Loop Termination PCBs occupying Loop Termination position LT5
and greater should be incremented by one position.
Note: A Dual Pelican configuration does not normally operate with audibles.
3.14 Tactile Modules
The ST750ELV controller can be fitted with either switched or non-switched tactiles. Non-
switched tactiles are wired directly across the pedestrian green terminals, marked ‘TACT’, and
shown in Figure 55.
Switched and non-switched tactiles can be driven in parallel from each of the TACT outputs and
from the Audible Drive output ‘ADRV’. Limitations on number of tactiles that can be driven from
the two TACT outputs and the ADRV output should be sought from ST750ELV Handbook
(667/HB/32750/000).
Figure 55
Tactile and
Audible
Driver
Connections