Rev. 7 August 2021 40 41110485
3
3: Specifications
This chapter describes the FX30S gateway specifications.
Table 3-1: Specifications
Certification and
Interoperability
Emissions / Immunity • CE (Including EMC Test case for vehicle installation EN301489)
• ACMA RCM
• FCC
• Industry Canada
Safety • CB Report IEC 60950-1
• UL Listed
Industry
Certification for
Vehicles
• E-Mark UN ECE Regulation No. 10 Rev. 5
Environmental
Compliance
• RoHS 2011/65/EU (RoHS 2)
• WEEE
• REACH
GSM/HSPA+
Certifications
• PTCRB
• GCF
Environmental
Testing
Vibration
(operational)
MIL-STD-810G, test method 514.6C
Category 4 CWV (Composite Wheeled Vehicle)
Shock (operational) MIL-STD-810G, test method 516.6
SAE J1455 (Shock
and Vibration) for
heavy-duty vehicles
• Vibration: Section 4.10.4.2 Cab Mount
• Shock: Section 4.11.3.4 Operational Shock
• Electrical: 12 and 24 V systems
Section 4.13.1—12 and 24 V
Section 4.13.2—SAE J1113-11 Level IV
Temperature
(operational)
MIL-STD-810G, test methods 501.5, 502.5
(-30° to +75°C)
Note: Surface temperature is recorded as 82.3°C at 60°C ambient.
Final temperature code is subject to change when installed in end
enclosure.
Temperature
(non-operational)
MIL-STD-810G, test methods 501.5, 502.5
(-40° to +85°C)
Thermal shock MIL-STD-810G, test method 503.5
Humidity
(operational)
MIL-STD-810G, test method 517.5
95% RH over temperature range of +20°C to + 60°C
IP rating IP30
Drop (non-
operational)
ISTA 2A 2001, test categories 1, 4, 5, and 6