EasyManuals Logo

SIGLENT SSA3021X User Manual

SIGLENT SSA3021X
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
SIGLENT
SSA3000X User Manual 56
2.5 System
2.5.1 System
Set the system parameters.
2.5.1.1 Language
The analyzer supports multi-language menu, Chinese and English build-in help and popup
messages.
Press this key to select the desired display language.
2.5.1.2 Power On/Preset
1. Power On
Set the power on setting to Default, Last or one of user.
Def: Load the default settings, for more details please refer to Table 2-40.
Last: When Last is selected, settings before the last power-off would be recalled automatically
at power on.
User: If power on set to user, the device will recall the specified configuration after power on.
2. Preset
Set the preset type to Default, Last or one of User.
Def : When press Preset, load the default settings, for more details please refer to Table 2-40.
Last: When press Preset, load the last power-off settings.
User : When press Preset, load the specified configuration type.
3. User Config
Save the current instrument setting as user-defined setting into the internal non-volatile memory.
4. Factory
When factory is selected, the device will recall the initial config.
5. Reset & Clear
When Reset & Clear is selected, the device will recall the initial config and all user data and
settings will be erased.
2.5.1.3 Interface Config
The analyzer supports communications through LAN, USB and USB-GPIB as standard interface.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIGLENT SSA3021X and is the answer not in the manual?

SIGLENT SSA3021X Specifications

General IconGeneral
Frequency Range9 kHz to 2.1 GHz
Resolution Bandwidth (RBW)1 Hz to 1 MHz
Sweep Time1 ms to 1000 s
Input Impedance50 Ω
Input VSWR< 1.5
Maximum Input Level+30 dBm
Tracking GeneratorOptional
Displayed Average Noise Level (DANL)-161 dBm/Hz
InterfacesUSB Host, USB Device, LAN, GPIB (optional)
Display Resolution1024 points
Power Requirements100 V - 240 V AC, 50 Hz/60 Hz
Phase Noise-98 dBc/Hz @ 10 kHz offset (1 GHz carrier)