Wire Preparation Procedure
Power/Data (12-pin) Cable:
This is a 6-pair twisted cable. We recommend that the
main cable insulation (black plastic) be stripped about 5
inches back to expose the color-coded leads. Below are
the color and signal designation of the wires:
Pin 1 --- Red ----------- +10-32 VDC
Pin 2 --- Black -------- Negative GND.
Pin 3 --- Blue ------- NMEA TX1-
Pin 4 --- Brown ------- NMEA TX1+
Pin 5 --- Orange --------- NMEA RX1-
Pin 6 --- Green ------ NMEA RX1+
Pin 7 --- Yellow -------- NMEA TX2 -
Pin 8 --- White ------- NMEA TX2+
Pin 9 --- Purple ---- NMEA RX2-
Pin 10 -- Grey ------ NMEA RX2+
Pin 11 -- Lite Green -- GND Fast Channel IN
Pin 12 ------------ GND
Strip the individual wire insulation about 1/2 inch to
make it more convenient to connect the wires to a ter-
minal strip posts. Use electrical tape or shrink tubing to
protect exposed shield wires. Use a 20-position terminal
strips to terminate the Pwr/Data and Auxilary cables.
This item is not supplied with the product, we suggest
getting it from a local electronic store.