10. Malfunctions Page 54
EN
Danger!
Performing work on an energized pump or
product may result in serious injury or
death. Assembly, maintenance, and repair
work may only be performed on products
that have been de-energized by qualified
technical personnel. The supply voltage
must be switched off before opening any of
the product's components.
Danger!
The hot surface of a motor may cause
burns. Motor surfaces may only be
touched with appropriate gloves or after
the motor has been shut off for an
extended time.
Danger!
Centralized lubrication systems are
pressurized during operation. Centralized
lubrication systems must therefore be
depressurized before starting assembly,
maintenance or repair work, or any system
modifications or system repairs.
Dismantling of the product or individual
parts thereof within the statutory warranty
period is not permitted and voids any
claims.
All assembly, maintenance and repair work
beyond this scope must be performed by
the Service department of SKF Lubrication
Systems Germany GmbH .
Only original spare parts from SKF
Lubrication Systems Germany GmbH may
be used. Unauthorized alterations to
products and the use of non-original spare
parts and accessories are not permitted.
Continuation of Table 29 Fault analysis and rectification
Malfunction
Possible cause
Rectification
Excessive lubricant at
all lubrication points.
Metering volume too high.
Increase the interval time.
Individual lubrication
points are not
supplied.
Lubrication line is clogged.
Clean lubrication lines.
Lubrication line bent or broken.
Replace affected lubrication lines, insert filled lubrication
lines.
Distributor defective.
Replace entire piston pump unit.
Lubrication line too long.
Relocate the piston pump unit, shorten lubrication lines
(max. 6 m).
Individual lubrication
points receive
insufficient or
excessive lubrication.
Metering volume too low or too
high.
Connect the secondary feeder, if required, install a second
pump unit with a reduced delivery rate to supply the second
distributor. Supply lubrication points with lower lubrication
requirements using the secondary distributor (2nd
distributor) and lubrication points with higher lubrication
requirements using the master distributor. In case of
insufficient lubrication, reduce the interval time. In case of
excessive lubrication, prolong it accordingly.
Please contact SKF.